Geofill LD Physical Properties
CO EFFICIENCY OF PERMEABILITY
*As determined by method of U.S. Army Corps of Engineers, EDM, 1110-2-1906 and ASTM D2434
WATER ABSORBTION
*Long term total immersion as percent of cast density per method of ASTMC796
RESISTANCE TO RAPID FREEZING & THAWING
* As determined by methods of ASTM C 666 modified to allow for the insulating properties of GeoCell.
| CLASS II | CLASS IV | |
| Maximum Cast Density, PCF | 30 | 42 |
| Co efficiency of Permeability, k, cm/sec | ||
| @ Effective Confining Stress, 2.5 PSI | 4.7 x 10 -5 | 1.5 x 10 -6 |
| @ Effective Confining Stress, 18 PSI | 1.9 x 10 -5 | 5.4 x 10 -7 |
*As determined by method of U.S. Army Corps of Engineers, EDM, 1110-2-1906 and ASTM D2434
WATER ABSORBTION
| CLASS II | CLASS III | CLASS IV | |
| Maximum Cast Density, PCF | 30 | 36 | 42 |
| % Water Absorbtion After 120 Days | 20 | 16 | 14 |
*Long term total immersion as percent of cast density per method of ASTMC796
RESISTANCE TO RAPID FREEZING & THAWING
| NUMBER OF FREEZE - THAW CYCLES |
CLASS II
(30 PCF)
|
CLASS IV
(40 PCF)
|
| 30 | 98 | 98 |
| 80 | 90 | 95 |
| 120 | 86 | 90 |
| 330 | 70 | 79 |
| Relative "E" Percent at Cast Density | ||
* As determined by methods of ASTM C 666 modified to allow for the insulating properties of GeoCell.