Toll Free
GeoTechnicalCellular
SocialTwist Tell-a-Friend 
CO EFFICIENCY OF PERMEABILITY
  CLASS II CLASS IV
Maximum Cast Density, PCF 30 42
Co efficiency of Permeability, k, cm/sec    
@ Effective Confining Stress, 2.5 PSI 4.7 x 10 -5 1.5 x 10 -6
@ Effective Confining Stress, 18 PSI 1.9 x 10 -5 5.4 x 10 -7

*As determined by method of U.S. Army Corps of Engineers, EDM, 1110-2-1906 and ASTM D2434

WATER ABSORBTION
  CLASS II CLASS III CLASS IV
Maximum Cast Density, PCF 30 36 42
% Water Absorbtion After 120 Days 20 16 14

*Long term total immersion as percent of cast density per method of ASTMC796

RESISTANCE TO RAPID FREEZING & THAWING
NUMBER OF FREEZE - THAW CYCLES
CLASS II
(30 PCF)
CLASS IV
(40 PCF)
30 98 98
80 90 95
120 86 90
330 70 79
  Relative "E" Percent at Cast Density

* As determined by methods of ASTM C 666 modified to allow for the insulating properties of GeoCell.
News & PressView All
Mixonsite utilized a Geofill Hybrid material containing anti-washout admixtures to fill an abandoned ash pit at the Consolidated Edison site in Brooklyn, NY. Free water within the pit was removed during placement to maintain the specified pit water level.
 
MixOnSite pumped Geofill LD cellular concrete material nearly 3 miles at Brightwater East tunnel project. Material produced on site with high production equipment featuring colloidal mixers.
 
MixOnSite recently developed an innovative foam product to transport solid materials such as mine tailings or waste crusher sands through a pipeline.